The compliance register that has read the paperwork

Track every statutory duty across your portfolio, generate the maintenance programme from your asset register, and have AI read the certificates you already hold. 91 UK regimes configured out of the box.

Including the duties you hold no record for.

UK regimes
91UK regimes
statutory duties
63statutory duties
asset types
133asset types
maintenance tasks
1053maintenance tasks

A compliance system that fills itself in

Most compliance software is bought and then abandoned half-configured, because somebody has to decide what to track and type it all in. That is the job you were trying to buy your way out of.

The register, including the gaps

Tell us the property type and the duties that apply appear — every type in the catalogue carries at least 54. Each one shows as valid, expiring, overdue or missing. A duty with no record at all is shown as loudly as an expired one, because to an enforcing authority it usually is worse.

Maintenance you do not type

Register a passenger lift and you get its monthly alarm test and its six-monthly LOLER examination, tasks already written. 1,053 tasks across 133 asset types, each on the right frequency. A late visit never shifts the cycle.

Inspections on a phone

18 ready-made forms with 169 checks between them — fire doors, emergency lighting, extinguishers, roofs — each with its pass condition and the standard behind it. Photograph what you find, sign it off, and turn a failed check into a tracked action in one tap.

AI that reads your certificates

Upload an EICR or a fire risk assessment and have its dates, certificate number and remedial actions extracted, each citing the page it came from. Nothing it finds counts towards compliance until you have checked it against that page and accepted it.

Contractors close out their own jobs

Give a supplier a login that shows only their work, in only their buildings. They report a job done and upload the certificate; you close it when you hold the evidence. Their uploads land in the document store and become searchable.

Ask it questions

Which buildings have an expired EICR? When was the lift last serviced? What is still open from the last fire risk assessment? The assistant answers from the register and from the documents behind it, and says where each answer came from.

What is covered

91 regimes across every property type — residential, mixed-use, office, retail, industrial, healthcare, education and leisure. Each one cites the regulation or standard it comes from.

  • Fire safety

    23

    FRA · Fire doors (common) · Flat entrance doors · Fire alarm

  • Electrical

    12

    EICR · PAT · HV switchgear · EV charging

  • Fabric, asbestos & environment

    12

    Asbestos survey · Asbestos re-inspection · EPC · Fall arrest

  • Lifts & vertical transport

    9

    LOLER (passenger) · LOLER (goods) · Lift service · Lift alarm

  • Water & legionella

    8

    Legionella RA · Water monitoring · Tank inspection · TMV servicing

  • Workplace health & safety

    7

    H&S risk assessment · DSEAR · Racking · Access audit

  • Air, ventilation & refrigerants

    6

    TM44 · F-Gas · LEV (COSHH) · TR19 Grease

  • Building Safety Act

    6

    BSR registration · Safety case · Assessment certificate · MOR log

  • Gas & heating

    5

    Gas safety (CP12) · Commercial gas · PSSR · Oil storage

  • Security systems

    3

    Intruder alarm · CCTV · Access control

Standards and regulations cited

Regulatory Reform (Fire Safety) Order 2005, article 9 · Fire Safety Act 2021 · Fire Safety (England) Regulations 2022, regulation 10 · BS 5839-1 · BS 5266-1 / BS EN 50172 · BS 5306-3 · BS 9990 · BS 7346-8 / BS EN 12101 · BS 9999 Annex B / BS EN 15650 · BS 8524-2 · BS 7671 · Electricity at Work Regulations 1989 · IET Code of Practice · manufacturer's schedule · BS 7671 section 722 · IET Code of Practice for EV Charging Equipment · BS 7671 section 712 · MCS installation standards

How the compliance register works

  1. 1

    Add a building

    Pick the property type and the duties that apply are suggested for you. Mark a building as higher-risk and the Building Safety Act duties appear alongside the rest.

  2. 2

    Record what has been done

    Enter the last date and certificate for each duty, or upload the certificates in one go. On Pro, AI reads each one and proposes the dates and remedial actions for a person to check.

  3. 3

    See what is due, done and missing

    Every duty shows when it was last done, when it is next due, and where no record is held at all. Remedial actions carry a priority and a deadline.

  4. 4

    Stay ahead of the dates

    Email reminders go out before duties fall due. Completed PPM visits and signed-off inspections are logged against their duty, and the register exports to CSV with the gaps listed as well as the records.

Every statutory duty on the register

The 63 statutory duties PM Assist tracks, with the law or standard each comes from and its usual interval. Best-practice duties — insurer requirements, manufacturers’ schedules — are on the register too, and the product marks which are statutory so the two are never confused.

Fire safety (18)
DutyComes fromInterval
Fire Risk AssessmentRegulatory Reform (Fire Safety) Order 2005, article 9; Fire Safety Act 2021Reviewed annually, renewed on risk
Fire Door Checks — Common PartsFire Safety (England) Regulations 2022, regulation 10Quarterly
Fire Door Checks — Flat Entrance DoorsFire Safety (England) Regulations 2022, regulation 10Annually
Fire Alarm & Detection ServiceBS 5839-1 (non-domestic) / BS 5839-6 (domestic)Every 6 months
Emergency Lighting TestBS 5266-1 / BS EN 50172Monthly function test, annual duration test
Fire Extinguisher ServiceBS 5306-3 (maintenance) / BS 5306-8 (provision)Annual basic service
Dry Riser TestBS 9990Annual pressure test, 6-monthly visual
Wet Riser TestBS 9990Annual test, weekly pump test
Smoke Control & AOV ServiceBS 7346-8 / BS EN 12101Annual service, monthly test
Fire Damper Drop TestBS 9999 Annex B / BS EN 15650Annually
Fire Curtain & Shutter ServiceBS 8524-2Every 6 months
Fire Evacuation DrillRegulatory Reform (Fire Safety) Order 2005, arts. 15 & 21At least annually
Voice Alarm (PAVA) ServiceBS 5839-8Every 6 months
Emergency Voice Communication (Refuge & Fire Telephones)BS 5839-9Annual service
Gas Suppression System Service & Room Integrity TestBS EN 15004-1; BS ISO 145206-monthly service, annual integrity test
Fire Safety Information to ResidentsFire Safety (England) Regulations 2022On moving in, then every 12 months
Firefighting Lifts & Equipment Monthly CheckFire Safety (England) Regulations 2022Monthly
Secure Information Box & Building PlansFire Safety (England) Regulations 2022Kept current; reviewed at least annually
Lifts & vertical transport (8)
DutyComes fromInterval
LOLER Thorough Examination — Passenger LiftLifting Operations and Lifting Equipment Regulations 1998, regulation 9Every 6 months
LOLER Thorough Examination — Goods LiftLifting Operations and Lifting Equipment Regulations 1998, regulation 9Every 12 months
Lift MaintenanceBS EN 13015; supports LOLER and PUWERQuarterly
Lift Emergency Alarm TestBS EN 81-28Monthly
Escalator & Moving Walk MaintenanceBS EN 115-2; Provision and Use of Work Equipment Regulations 1998Quarterly service, annual safety inspection
Automatic Door Safety InspectionBS EN 16005; Provision and Use of Work Equipment Regulations 1998Every 6 months
BMU & Access Cradle — LOLER Thorough ExaminationLifting Operations and Lifting Equipment Regulations 1998, reg. 9Every 6 months
Forklift Truck — LOLER Thorough ExaminationLifting Operations and Lifting Equipment Regulations 1998Every 12 months (6 if lifting people)
Electrical (7)
DutyComes fromInterval
Electrical Installation Condition ReportBS 7671 (IET Wiring Regulations); Electricity at Work Regulations 1989Every 5 years
In-Service Inspection of Electrical EquipmentElectricity at Work Regulations 1989; IET Code of Practice (5th edition)Risk-based, commonly annual
HV Switchgear MaintenanceElectricity at Work Regulations 1989; manufacturer's scheduleEvery 1–3 years
EV Charging Point InspectionBS 7671 section 722; IET Code of Practice for EV Charging EquipmentAnnually
Solar PV InspectionBS 7671 section 712; MCS installation standardsAnnually
Powered Gates, Barriers & Roller Shutters ServiceProvision and Use of Work Equipment Regulations 1998; BS EN 12453Every 6 months
Waste Compactor & Baler InspectionProvision and Use of Work Equipment Regulations 1998Annually (service and inspection)
Water & legionella (7)
DutyComes fromInterval
Legionella Risk AssessmentACOP L8; HSG274; Health and Safety at Work etc. Act 1974Reviewed every 2 years, or on change
Legionella Control MonitoringACOP L8; HSG274 Part 2Monthly temperature monitoring
Cold Water Storage Tank InspectionHSG274 Part 2; BS 8558Annually
Thermostatic Mixing Valve ServicingHSG274 Part 2; HTM 04-01 (healthcare); BS 7942Annually, 6-monthly in healthcare
Backflow Prevention Device TestWater Supply (Water Fittings) Regulations 1999Annually
Cooling Tower Notification & TreatmentNotification of Cooling Towers and Evaporative Condensers Regulations 1992; HSG274 Part 16-monthly clean, weekly monitoring
Shower Head Cleaning & DescalingHSE HSG274 Part 2; ACOP L8Quarterly
Fabric, asbestos & environment (6)
DutyComes fromInterval
Asbestos Management SurveyControl of Asbestos Regulations 2012, regulation 4; HSG264Once, then kept up to date
Asbestos Re-inspectionControl of Asbestos Regulations 2012, regulation 4; HSG264At least annually
Energy Performance CertificateEnergy Performance of Buildings (England and Wales) Regulations 2012Every 10 years
Fall Arrest & Anchor Point InspectionWork at Height Regulations 2005; LOLER 1998 regulation 9 for personal fall protection equipment; BS 7883Every 12 months
Waste Duty of CareEnvironmental Protection Act 1990, s.34; Waste (England and Wales) Regulations 2011Carrier checks annually; notes kept 2–3 years
Heat Network NotificationHeat Network (Metering and Billing) Regulations 2014Every 4 years
Building Safety Act (6)
DutyComes fromInterval
BSR Building RegistrationBuilding Safety Act 2022, section 78; Higher-Risk Buildings (Registration Procedure) Regulations 2023Once, then kept current
Safety Case ReportBuilding Safety Act 2022, sections 83–85Reviewed annually, revised on change
Building Assessment CertificateBuilding Safety Act 2022, sections 79–82On direction from the Regulator
Mandatory Occurrence ReportingBuilding Safety Act 2022, section 87; Higher-Risk Buildings (Management of Safety Risks etc.) Regulations 2023Continuous; reviewed annually
Resident Engagement StrategyBuilding Safety Act 2022, sections 91–93Reviewed every 2 years
Golden Thread InformationBuilding Safety Act 2022; Higher-Risk Buildings (Management of Safety Risks etc.) Regulations 2023Continuous; reviewed annually
Gas & heating (4)
DutyComes fromInterval
Landlord Gas Safety RecordGas Safety (Installation and Use) Regulations 1998, regulation 36Every 12 months
Commercial Gas Safety InspectionGas Safety (Installation and Use) Regulations 1998; IGEM/UP standardsAnnually
Pressure Systems Written Scheme ExaminationPressure Systems Safety Regulations 2000Per the written scheme (typically 12–36 months)
Oil Storage Tank InspectionOFTEC TI/133; Control of Pollution (Oil Storage) Regulations 2001Annually
Air, ventilation & refrigerants (4)
DutyComes fromInterval
Air Conditioning Inspection (TM44)Energy Performance of Buildings (England and Wales) Regulations 2012; CIBSE TM44Every 5 years
F-Gas Leak CheckRetained Regulation (EU) 517/2014; Fluorinated Greenhouse Gases Regulations 2015Set by refrigerant charge (CO₂e)
LEV Thorough Examination & TestControl of Substances Hazardous to Health Regulations 2002, regulation 9; HSG258At least every 14 months
Kitchen Extract Cleaning (TR19 Grease)BESA TR19 Grease; Regulatory Reform (Fire Safety) Order 2005Set by cooking hours per day
Workplace health & safety (3)
DutyComes fromInterval
Health & Safety Risk AssessmentManagement of Health and Safety at Work Regulations 1999, reg. 3Reviewed annually, and on change
DSEAR Risk AssessmentDangerous Substances and Explosive Atmospheres Regulations 2002, reg. 5Reviewed regularly, and on change
Storage Racking InspectionProvision and Use of Work Equipment Regulations 1998; BS EN 15635 / SEMAExpert inspection every 12 months

Compared with a spreadsheet or a CAFM

Most teams track compliance in a spreadsheet and a shared drive, or in an enterprise CAFM used for a fraction of what it does.

Spreadsheet + shared driveEnterprise CAFMPM Assist
UK duties set up for youBuild it yourselfUsually configured in an implementation project91 duties, out of the box
Shows duties with no record heldOnly if someone noticesDepends on configurationYes, per building
Reads certificates for youNoVaries by productYes, on Pro — a person checks each one
Search inside O&M manualsFile names onlyUsually stored, not searched insidePlain-English answers with the page cited
Time to first buildingDays of setupTypically an implementation projectMinutes, self-serve
Price to startStaff timeQuote and contractFree, then from £59/month

AI reads it. A person signs it off.

Reading a fire risk assessment and pulling out twenty remedial actions is the single biggest time saving here. It is also the place where being wrong matters most, so it is built to be checked rather than trusted.

  • Everything AI produces is a proposal. It is excluded from every compliance figure — it cannot turn a red building green, is not counted as open work, and chases nobody by email.
  • Every extraction cites the page it came from, and the review screen links straight to it. A finding that cannot be attributed to a page is discarded rather than kept at lower confidence.
  • Accepting a proposal records who accepted it and when. Until somebody does, it does not count.
  • Dates must be unambiguous. UK certificates and American software write dates in opposite orders, so anything that cannot be read with certainty is dropped rather than guessed at.

PM Assist never asserts that a building is compliant on the strength of a machine’s reading. A person does, having been shown the page it came from.

Questions

What is compliance register software?
A compliance register lists every duty a building carries — statutory and good practice — with when each was last done, when it is next due and the evidence that it was. Compliance register software keeps that list for every building, flags what is overdue or has no record at all, and holds the certificates behind each entry. PM Assist's register starts with 91 UK duties configured and filtered by property type, so you begin from the list that applies rather than a blank sheet.
How much does it cost?
PM Assist is free on one building, with no credit card. The compliance register, planned maintenance and inspections are included in every paid plan. Paid plans start at £59 a month; the pricing page lists what each plan includes.
What is building compliance software?
Building compliance software tracks the statutory duties a property carries — fire risk assessments, electrical installation condition reports, gas safety checks, legionella control, lift examinations, asbestos management and more — along with the evidence that each one has been discharged, and the remedial actions arising. PM Assist ships with 91 UK regimes configured, 63 of them statutory, so a new building's register can be stood up without deciding what to track.
How is this different from a CAFM system?
A CAFM system holds the schedule and the register but treats certificates as attachments: you can see that a document exists, not what is in it. PM Assist holds both. The compliance register and the planned maintenance work the way a CAFM system's do, and the documents behind them are read, indexed and searchable — so you can ask what the last EICR actually said, not just when it was filed.
Does it cover the Building Safety Act and higher-risk buildings?
Yes. Mark a building as higher-risk and the golden thread duties appear alongside the rest: BSR registration and Key Building Information, the safety case report, the building assessment certificate, mandatory occurrence reporting, the resident engagement strategy, and the requirement to hold building safety information digitally. They are hidden on buildings that are not higher-risk, so an office is never shown a resident engagement strategy.
Can AI read our existing certificates?
It can read a certificate or report and propose what it says — which regime it evidences, the issue and expiry dates, the certificate number, the contractor, and any remedial actions with the page each came from. Everything it produces is a proposal. It is excluded from every compliance figure until a person has checked it against the source page and accepted it, so an AI reading can never by itself mark a building compliant.
What property types does it cover?
Residential blocks, mixed-use, offices, retail, industrial, healthcare, education and leisure. The duties shown are filtered by property type — every type carries at least 54 duties in the catalogue — so you see what applies to the building in front of you rather than a generic list.
Do I have to type in all our maintenance schedules?
No, and this is usually the reason a compliance system gets abandoned half-configured. Register an asset and its maintenance programme is generated from a library of 133 asset types and 1,053 tasks, each already on the right frequency. Adding a passenger lift produces its monthly alarm test and its six-monthly LOLER examination with the tasks written.
Can our contractors use it?
Contractors can be given a login that shows only the jobs assigned to their company, in buildings assigned to their company. They report a job complete with notes and upload the certificate; you close it once you are satisfied with the evidence. Their uploads go into the building's document store and become searchable like anything else.
Can we get the register out for an auditor?
Yes — the compliance register, the remedial actions and the asset list all export to CSV. The register export lists every duty that applies, not only the ones you hold a record for, so the gaps are visible in the document an auditor opens rather than absent from it.

Stand a building up in an afternoon

Tell us what the property is and what plant it has. We supply the duties, the tasks and the intervals. Start free on one building — no credit card.

Intervals in the catalogue are typical for each standard and are a starting point. The interval that applies to your building may be shorter — set by your risk assessment, your insurer or the equipment itself. Always confirm against the current regulation and your own assessments.

See also: maintenance checklists, inspection checklists and statutory compliance explained.